> DDS Function Signal Generator
> Digital Multimeters
> Distortion Analyzer
> Four Probe experiment
> Function Generator
> IC Testers
> LCR Meters
> Oscilloscopes
> Power Supplies
> Pulse Wave Frequency Meter
> Signal / Function Generator
> Storage Oscilloscopes
> Two Probe Setup
> Withstand Tester
> General Physics Equipments
 
- Digital Micro Volt Meter
- Digital Nano Ammeter
- Digital Pico Ammeter
- Digital Gaussmeter
- Magnetic Field Measurement Apparatus
- Study of Dieletric Constant & Curie Temp of Ferroelectric Ceramics
- e/m Experiment
- Planck’s Constant by Photoelectric Effect
- Determination of Planck’s Constant by means of LED’s
- Frank Hertz Experiment
- Ionisation Potential Set-up
- Measurement of Magnetoresistance of Semiconductors
- Two Probe Method for Resistivity Measurement of Insulators
- Electron Spin Resonance Spectrometer
- Study of Thermoluminescence of F-centres in Alkali Halide Crystals
- Hall Effect in Metals
- Dependence of Hall Coefficient on Temperature
- Apparatus for the Measurement of Susceptibility of Paramagnetic Solution by Quinck's Tube Method
- Apparatus for the Measurement of Susceptibility of Solids by Gouy’s Method
- Magnetic Hysteresis Loop Tracer
   
> TEKON INSTRUMENTS
  - T100 Network Cable Detector
  - T550 Power Quality Analyzer
  - T560 Power Quality Analyzer
  - T600 Txr Turn to Ration
  - T610 Txr Analyzer
  - T650 ESS Diagnostic
  - T700 Ind. Robot Diagnostic
  - T800 EV-HEV Diagonstic
 
   
   
   
   
 
 
     
 
General Physics Equipments
 
Digital Pico-ammeter
  • Measures current down to 1pA
  • All solid state and IC design
  • Very low offset current

Features

This is a very versatile multipurpose equipment for the measurement of low dc currents. It has 6 decade ranges with 100% over-ranging from 10-9A to 10-4A. For the ease, readings are directly obtained on a 3½ digit DPM.

The instrument uses a well designed precision FET input electrometer operational amplifier AD549, which offers the lowest input bias currents (50fA with 10fA ±5V supplies) available in any standard operational amplifier. The excellent characteristics of AD549, ultra low bias current, low offset voltage, low drift and low noise have been fully utilized to obtain best results in the present picoammeter. The first operational amplifier AD549 is used in low level current to voltage configuration and the output has been directly read on a 3½ digit panel meter. The instrument is capable of accepting either polarity of the input current. Well regulated power supplies are incorporated to use the instrument upto 10% changes in a.c. main’s voltage

Applications

  • Current from Photomultiplier tubes, Photometers etc.
  • Leakage currents in solid state devices.
  • FET gate and tube grid-voltage without loading errors
  • Current through very high resistance’s in conjunction with a power supply
  • Potentials across semiconductors, piezoelectric system & pH/plon sensitive electrodes
  • Electrical conductivity of air
  • Very low current oxygen sensors

Specifications

Multiplier X1X10 to the power 2, X10 to the power 3, X10 to the power 3, X10 to the power 4
Accuracy 0.2% for all ranges
Resolution 1pA, 10pA, 100pA, 1nA, 10nA, 100nA
Input Resistance 2.5KW, 0.25KW, 25W, 2.5W, 0.25W, 0.025W
Display 3½ digit 7 segment LED with auto polarity and decimal indication
Input Through amphenol connector
Power Supply 220V ±10%, 50Hz
Weight 2.5Kg
Dimensions 240mm X 275mm X 120mm
 

 

* Products not listed can be ordered as per request.
* Model number may subject to change without intimation